WordPress WooCommerce Themes

Reagent dose for sludge dewatering: 9 g/m³

A low reported reagent dose as a direction for verification

Editorial material by Tymur Lievda, based on the work of Anatolii Mykhailovych Demchenko

What figures the reports give

For DEMKUL, a recommended dose of 9 kg per 1,000 m³ of sludge is stated, that is, 9 grams per cubic metre. In the second trial, the use of 100 kg of the composition per 12,842 m³ was reported, which corresponds to about 7.79 g/m³. This is one of the most interesting figures for repeat verification. [1]

How to convert to tonnes of dry solids

International publications often give dosing in kilograms of reagent per tonne of dry solids. Assuming, for illustration, a slurry density of 1 t/m³ and an average moisture content of 96.4%, one cubic metre would contain 36 kg of dry solids. The recommended 9 g/m³ would then correspond to about 0.25 kg of composition per tonne of dry solids, and the reported actual consumption to 0.216 kg/t.

This is an editorial conversion based on an assumed density, not a measured specific dose. The share of active substance in DEMKUL is not specified in the reports provided.

An international benchmark and the case for further study

In Alfa Laval’s 2026 industrial case, for a different sludge, 4.1 kg/t of dry solids is given for the screw press and 2.5 kg/t for the centrifuge. The source is a manufacturer’s material, not an independent trial of DEMKUL. [2]

The reported DEMKUL doses look promising for testing the cost-effectiveness of the reagent. However, the difference in numbers should not be presented as a proven multiple of savings: this requires identical rules for accounting for the active substance, the exact mass of dry sludge, control of dosing and comparable final moisture. A repeat pilot could make this argument considerably stronger.

Sources

  1. Demchenko A. M. Report on industrial trials in the autumn–winter period (in Ukrainian). NDC FARMADEM LLC and Chernihivvodokanal municipal enterprise, 2014. File “Демкул_отчет_2.doc”.
  2. Alfa Laval. Full-scale comparison of decanter centrifuge and screw press performance for municipal sludge dewatering. 28.08.2026. Equipment manufacturer’s publication.

First article in the series